Natural Gas Safety Valve (Socket)
<p class="stock in-stock"></p>
Natural gas safety valve with a thermal device and quick connection. Available with a steel safety device (resistant up to 925 degrees), and with the brass safety device (resistant up to 650 degrees).
Also available without a thermal safety device.
Related products
-
General & Physical Tests, Machinery, Tools & Cable Components
Multi Die – Hydraulic Press Machine for Making Sample Molds
General & Physical Tests, Machinery, Tools & Cable ComponentsMulti Die – Hydraulic Press Machine for Making Sample Molds
0 out of 5(0)A hydraulic press is a multi-use device as it can be used to mold the plastic samples for several testing requirements as well as day to day inspection such as Color matching tabs can be made with it, Limiting oxygen index test samples as per ISO 4589 can be prepared. The use of it is quite simple, but the granules on the dies of expected shape and press it on prescribed temperature, and within some minutes you get your sample as required.
SKU: n/a -
General & Physical Tests
Low & Ultra-Low Temp Cold Chamber Machine (for -0 to -86 C )
0 out of 5(0)- Cold Chamber Size (as per requirement of customer)
- Digital Temperature Indicating controller
- Glass Window on the door. (if required)
- Very high displacement compressor of about 22 per revolution
- Highly efficient refrigerant R404A having a boiling pt. Of -46DegC
- Our freezer does not require a low ambient temp. It can work even at an ambient of 40DegC
- Feed evaporator to improve the refrigeration effect and coeff. Of performance of the system as a whole
- High density PUF of about 60kg/cm3 so as to hold the temperature for a longer time
- Hot discharge is circulated on the mouth of the freezer to prevent cooling losses
- Microprocessor based temperature controller for accurate temperature and longer compressor life.
- Standard compressor of 1 hp with Cascading Refrigeration System
- Copper Capillary of higher wall thickness to last longer
- Uniform capillary distribution on the surface of chamber for faster and uniform cooling within chamber.
- Double door formation (acrylic + normal) for better insulation
- Noise less operations
SKU: n/a -
General & Physical Tests
Cold Bend Test | Cold Impact Test
0 out of 5(0)IEC 60811-504 describes the cold bend test method for cables under low temperatures. The cold bend test on cable is only possible upto a maximum diameter of 12.5mm. The test is mainly conclusive to understand the flexibility and strength of plastic used over cable under low temperatures.
Whereas cold impact test on cables is performed according to IEC 60811-506. This test is mainly designed to simulate the plastic’s capacity to resist mechanical shock under cold environment.Here from a certain height, mandrels of specific weight are dropped on the cable.
SKU: n/a -
Automated Testing, General & Physical Tests, Machinery
Optical Profile Projector for cable
0 out of 5(0)We have all range of Profile projectors suitable for cable and automotive manufacturing sector. Market is flooded with inaccurate and camera based profile projectors that are actually not compliant with Vision systems but still expansive as them.
Automatic profile projector for cable used in Cable Dimension measurement of any shape of the cable. Available with Accredited calibration master, color measurement, from 36 mm to 108 mm diameter samples.IEC-60502-1 and EN 50525 describes the requirement of exact dimension measurement of the insulation, inner jacket and outer jacket of a cable and it’s core.
Where you actually lose money?
- Having higher Insulation wall thickness due to the operator’s running safety margin
- Ovality of extrusion head setting causes the inhomogeneous spread of compound over the conductor.
- Due to higher core diameter, each next process of cable manufacturing such as stranding, taping, braiding, armoring, shielding, inner sheathing, outer jacketing takes a minimum of 0.05% to 3% of extra material.
- An average-sized Cable manufacturer who consumes 10 Million euros of plastics per year losses around 300.000 € just because of non-optimized dimension of cables.
We also supply all the measuring components calibrated by NABL accredited master instruments so that accuracy and uncertainty are never a concern for our clients.
SKU: n/a