D344 High Voltage Tracking Test Machine

Availability:

<p class="stock in-stock"></p>


No description

(max file size 512 MB)

D344 High Voltage Tracking Test Machine

Specifications:-

Model Number:-D344

Standard:-IEC 60587

Power:-Electronic

Drip interval time:-0 – 99.99s continuously adjustable

Power supply:-AC220 (±10%) V / 50 HZ

Test Material:-PE, PVC and SRPVC

Material:-SUS 304 Stainless Steel

Temperature:-23 ± 2 ℃

Applied voltage:-AC/DC 100V ~ 6000 V±5% adjustable

Dimension:-L1245 * W723 * H2295 mm

Air pressure:-86 ~ 106 kpa

Product Description:-

IEC60587 High Voltage Tracking Test Machine

  1. Application:-

High voltage tracking for testing the resistance to electric tracing and testing equipment is suitable corrosion of electrical appliances and its materials. The resistance to and electronic products, household electric tracing materials is evaluated by measuring to the requirements of the resistance to electric tracing and corrosion and corrosion of electrical insulation of liquid contaminants and oblique samples at power frequency. Its design conforms GB/T6553-2003 and IEC60587-1984 standards.

  1. Standards:- GB/T6553-2003 and IEC60587-1984
  2. Main Technical Parameters:-

(1) Applied voltage: AC/DC 100V ~ 6000 V±5% adjustable.

(2) Applied current: AC/0 ~ 100mA±1% + 5d, DC/0 ~ 100 mA±1% + 3d.

(3)The output voltage drop exceed 5% when the current is measured of the test device should not at 60 mA of continuous 0.5s.

(4) Electrode: The thickness of the upper and 0.5 mm, which is lower electrodes, is 304 stainless steel

(5) The distance the upper and lower between is 50.0 mm±0.5 mm electrodes.

(6) Drip device: Drip rate can be adjusted can be adjusted, contaminated device height liquid flow at 0.075 ml/min – 0.9 ml/min, test time can be predicted.

(7) Drip interval time: 0 – 99.99s continuously adjustable.

(8) Contaminated liquid: phoenix pole be ethanol, ammonium chloride, isooctyl non-ionic wetting agent thyme centigrade should with water mixture. The resistivity or deionized contaminated solution of the distilled water at Omega’s

(9) Power supply: AC220 (±10%) V / 50 HZ

(10)Instrument dimensions: L1245 * W723 * H2295

Frequently Asked Questions:-

What is IEC 60587?

It describes an evaluation of electrical insulating two test methods for the severe ambient conditions at power materials for use under frequencies by tracking and erosion, using a liquid contaminant and inclined measurement of the resistance to plane specimens.

What is the purpose of the high voltage test?

Surge Test or impulse tests are very high or extra-high voltage Impulse Test Surge test or tests, carried of surges or lightning on the out for investing the influences transmission equipment.

what is a High Voltage Tracking Test Machine?

The High Voltage Tracking Resistance test method exposed installed in the is used to assess the susceptibility to tracking of insulating to high voltages outdoors Insulators materials that are open are often at the mercy of humidity.

 

D344 High Voltage Tracking Test Machine