Natural Gas Safety Valve (Socket)
<p class="stock in-stock"></p>
Natural gas safety valve with a thermal device and quick connection. Available with a steel safety device (resistant up to 925 degrees), and with the brass safety device (resistant up to 650 degrees).
Also available without a thermal safety device.
Related products
-
General & Physical Tests
Cold Bend Test | Cold Impact Test
0 out of 5(0)IEC 60811-504 describes the cold bend test method for cables under low temperatures. The cold bend test on cable is only possible upto a maximum diameter of 12.5mm. The test is mainly conclusive to understand the flexibility and strength of plastic used over cable under low temperatures.
Whereas cold impact test on cables is performed according to IEC 60811-506. This test is mainly designed to simulate the plastic’s capacity to resist mechanical shock under cold environment.Here from a certain height, mandrels of specific weight are dropped on the cable.
SKU: n/a -
General & Physical Tests
Hot Air Bath (Underground, Above Ground all Size Possible)
0 out of 5(0)• The gap between the walls is filled up with special grade glass wool for proper
insulation to avoid heat losses.
• Temperature Control, Thermostat (Temperature accuracy +/- 3 Deg C)
• On/Off Control (Temperature accuracy +/- 2 Deg C)
• PID Control (Temperature accuracy +/- 1 Deg C)
• Microprocessor control (Temperature accuracy +/- 0.5 Deg C
• Please specify the kind of controller and accuracy required at the time of
ordering.
• Water Circulation
• Water circulation using separate motor or stirrer.
• Elements
• Heating elements are made of high quality heaters which are put inside the
water bath and placed at the bottom of the bathSKU: n/a -
Automated Testing, General & Physical Tests
Universal Tensile Strength Testing Machine for Plastics
0 out of 5(0)Universal tensile test machine are largely used as cable and plastic test equipment. The tester can complete one test with a simple five-step operation: select the existing test method, input the sample size, install the sample, start the test, and print the report. There two models with different variants of force as per the requirements of customers.
- Single column UTM invariants from 0.5KN to 10KN.
- Dual column UTM invariants from 1KN to 15KN.
SKU: n/a -
General & Physical Tests
Horizontal Cold Chamber up to -86 deg
0 out of 5(0)Techtrivial designs and develop many ranges of cold chambers for cable and plastic compounding industry. Our range goes from -23 Degree Celsius to -86 degree Celsius where you can test not only servo cables with -15 degree Celsius operating temperature but also Arctic grade cables up to -86 degree Celsius.
SKU: n/a