Smoke Density Chamber - Tech Trivial Cable & Electrical Test Equipments Suppliers Wed, 10 Aug 2022 12:42:23 +0000 en-US hourly 1 https://wordpress.org/?v=6.9 https://www.techtrivial.com/wp-content/uploads/2021/05/cropped-favi-32x32.png Smoke Density Chamber - Tech Trivial 32 32 IEC61034 Wire and Cable Smoke Density Test Chamber https://www.techtrivial.com/product/wire-and-cable-smoke-density-test-chamber/ Thu, 30 Sep 2021 09:22:38 +0000 https://www.techtrivial.com/?post_type=product&p=6809 D348 | IEC61034 Wire and Cable Smoke Density Test Chamber

Specifications:-

Model Number:-D348

Measurable transmittance range:-0% ~ 100%

Power:-Electronic

Nominal power:-100 W

Light source:-Imported quartz halogen lamp

Standard:-IEC61034

Fuel:-1.00L±0.01L alcohol

Test Material:-Cables & optical cables

Material:-SUS 304 Stainless Steel

Dimension:-L3 * W3 * H3 m

nominal luminous flux:-2000Lm ~ 3000Lm

Product Description:-

 Description:-

This equipment is according to GB/T17651.1-2-1998 “Determination designed and manufactured of smoke density of under specific conditions”. The optical measuring cables and optical cables burning system for or optical cables transmission of smoke or optical cables when they emitted under certain conditions smoke density burned by cables consists of a light source, receiver and a computer system. The light generated by the light a silicon photovoltaic cell source passes Laboratory of 3M 6550 The beam intensity of the light source. When a large amount of smoke is produced in the combustion chamber through a smoke density due to the cables, the smoke absorbs part of the photovoltaic, and the beam intensity combustion of cables or optical of the silicon photovoltaic cell is weakened. By processing the data with a linear response of 100% relative to the initial time can be calculated. This equipment is suitable for the computer system, the transmittance measuring the from cables are burned horizontally under certain conditions.

 Main Technical Parameters:-

The 1.5 mm thick SUS304 stainless steel plate is fixed on the square combustion chamber through a during the bracket to form the entire cube combustion chamber. Size: L3 * W3 * H3 m with a, and a transparent sealing on both sides to let the beam window is arranged on the opposite Structure: The front face is provided window measuring device pass through. The fan with a wall of the horizontal light glass observation electric valve. After top is equipped with an exhaust for each test, the from pipe with a valve. The valve should be closed test and keep good smoke should be completely discharged sealing performance.

Frequently Asked Questions:-

What is the Cable Smoke Density Test?

It is designed to generate when cables are burned. The Cable Smoke determines the volume of smoke Density Test is a Zero Halogen cable and is custom-built wide by 3 meters deep conducted inside a primarily performed on Low Smoke by 3 meters high – hence chamber measuring 3 meters the three meters cube test name.

What is IEC 61034?

It provides details of for under defined conditions, for example measuring smoke emission when electric the test apparatus to be used or optical fiber cables are burnt, a few cables burnt horizontally.

 

D348 | IEC61034 Wire and Cable Smoke Density Test Chamber

 

You can also check out our more Machinery Products.

]]>
ASTM E622 NBS Smoke Density Chamber / Test Machine https://www.techtrivial.com/product/nbs-smoke-density-chamber-test-machine/ Thu, 30 Sep 2021 09:18:37 +0000 https://www.techtrivial.com/?post_type=product&p=6811 ASTM E622 NBS Smoke Density Chamber / Test Machine

Specifications:-

Power:-Electronic

Test Material:-Plastics

Standard:-ASTM E622

Model Number:-D347

Ambient temperature:-Room temperature 15-30℃

Smoke chamber size:-900(L) x 610(W) x 900(H) mm

Dimension:-1822(L) x 860(W) x 1970(H) mm

Measurement range:-0-100%

Material:-SUS 304 Stainless Steel

Measurement accuracy:-± 3%

Working voltage:-AC220V, 50Hz

 Main technical parameters
Measurement range 0-100%
Measurement accuracy ±3%
Working voltage AC220V, 50Hz
Ambient temperature Room temperature 15-30℃
Relative humidity ≤ 80%
Light transmission resolution 0.0001%
 

Gas source

Purity is at least 95%, propane gas, pressure is 170Kpa
A. Propane flow: 50 cm3/min
B. Air flow rate: 500 cm3/min
 

 

Test mode

Flameless to thermal radiation, and the test of the pilot flame is not used mode: the test is only subjected
Flame mode: A test in which burner flame in addition to heat radiation, with or the sample is subjected to a without fire.
Smoke chamber size 900(L) x 610(W) x 900(H) mm
Dimensions 1822(L) x 860(W) x 1970(H) mm
Heating power 2.6 KW; Total power: 3 KW.
Working environment When the instrument is running forced to avoid direct sunlight and no airflow.

 

Frequently Asked Questions:-

What is the Plastic Smoke Density test?

It is also known as to be used for measuring the smoke-producing the Exit Sign Smoke Test, is intended characteristics of combustion example, ASTM E1354 or decomposition plastics under controlled conditions Other smoke test apparatus, for Cone Calorimeter, E662 Smoke Density Chamber, etc

What is the difference between ASTM and ISO?

ASTM is a national of ISO organizations. ISO is an international organization that is a part organization that all countries including has representations from ASTM.

 

D347 | ASTM E622 NBS Smoke Density Chamber / Test Machine

 

You can also check out our more Machinery Products.

]]>