IEC 60587 - Tech Trivial Cable & Electrical Test Equipments Suppliers Thu, 26 May 2022 14:46:59 +0000 en-US hourly 1 https://wordpress.org/?v=6.9 https://www.techtrivial.com/wp-content/uploads/2021/05/cropped-favi-32x32.png IEC 60587 - Tech Trivial 32 32 IEC 60587 10KV High Voltage Current Leakage Tracking Index Tester https://www.techtrivial.com/product/high-voltage-current-leakage-tracking-index-tester/ Fri, 08 Oct 2021 10:43:51 +0000 https://www.techtrivial.com/?post_type=product&p=6723 IEC 60587 10KV High Voltage Current Leakage Tracking Index Tester

Specifications:-

Applied voltage:-AC/DC 100V ~ 10000 V±5% adjustable

Material:-SUS 304 Stainless Steel

Drip interval time:-0 – 99.99s continuously adjustable

Temperature:-23 ± 2 ℃

Power supply:-AC220 (±10%) V / 50 HZ

Air pressure:-86 ~ 106 kph

Power:-Electronic

Test Material:-PE, PVC and SRPVC

Model Number:-D401

Dimension:-L1245 * W723 * H2295 mm

Standard:-IEC 60587

Product Description

10KV High Tracking Index Tester Voltage Current Leakage

Application:-

High voltage tracking for testing the conforms to the requirements resistance to testing equipment is and corrosion of electrical and electronic suitable insulation materials is evaluated electric tracing products, materials. The resistance to electric tracing and corrosion household appliances and their electrical by measuring the liquid contaminants and oblique resistance to electric tracing and corrosion samples. Its design of GB/T6553-2003 and IEC60587-1984 standard

 

Main Technical Parameters

Applied voltage: AC/DC 100V ~ 10000 V±5% adjustable.

Applied current: AC/0 ~ 100mA±1% + 5d, DC/0 ~ 100 mA±1% + 3d.

The output measured should not exceed 5% when the voltage drop of the test device current at 60 mA of continuous 0.5s.

Electrode: lower electrodes are 0.5 mm, which is the thickness of the upper and is 304 stainless steel.

The distance lower electrodes to the upper and mm±0.5 mm are 50.0 the.

Frequently Asked Questions:-

What is tracking in High Voltage?

The High X (HVTR) test method is properties can high voltages a result that tracking paths are extent deteriorate to such users to the metric system, “kilo” is the assess tracking of insulating the susceptibility to materials outdoors. Their electrical insulation that is exposed to as a formed on the insulator surface

How do you test for High Voltage?

The testing is applied across a limit the short circuit current test by means of a high voltage occurred in the device specimen of insulation or equipment procedure is very simple. High voltage under A resistor is connected with series with the transformer in the event of breakdown under test.

Why high voltage test is required?

High Voltage the device type and the acceptable current amount of voltage applied to operate to check the effectiveness of its safety during testing is usually performed to qualify rated electrical conditions, away insulation. The objective sought during the high voltage testing will determine the flow.

You can also check out our more Machinery Products.

]]>
IEC 60587 6KV High Voltage Tracking and Erosion Resistance Test Apparatus https://www.techtrivial.com/product/high-voltage-tracking-and-erosion-resistance-test-apparatus/ Fri, 08 Oct 2021 10:41:49 +0000 https://www.techtrivial.com/?post_type=product&p=6725 IEC 60587 6KV High Voltage Tracking and Erosion Resistance Test Apparatus

Specifications:-

Temperature:-23 ± 2 ℃

Dimension:-L1245 * W723 * H2295 mm

Model Number:-D400

Applied voltage:-AC/DC 100V ~ 6000 V±5% adjustable

Material:-SUS 304 Stainless Steel

Standard:-IEC 60587

Drip interval time:-0 – 99.99s continuously adjustable

Test Material:-PE, PVC and SRPVC

Air pressure:-86 ~ 106 kappa

Power supply:-AC220 (±10%) V / 50 HZ

Product Description

IEC 60587 High Voltage Evaluating Resistance to Tracking Test Equipment for Tracking and Erosion

 Main Technical Parameters:-
Applied voltage AC/DC 100V ~ 6000 V±5% adjustable
Applied current AC/0 ~ 100mA±1% + 5d, DC/0 ~ 100 mA±1% + 3d
Output voltage drop of the test device Should not is of exceed 5% when measured at 60 mA current continuous 0.5s.
Electrode The thickness of the which is 304 stainless steel upper and lower electrodes is 0.5 mm
Distance The distance between the upper and lower electrodes is 50.0 mm±0.5 mm.
Drip device Drip device contaminated liquid flow adjusted at 0.075 ml/min – 0.9 ml/min, height can be adjusted, the rate can be testing time can be predicted.
Drip interval time 0 – 99.99s continuously adjustable
Contaminated liquid Ammonium chloride, a non-ionic wetting agent with the distilled mixture. The resistivity, isooctyl phenyl polyethoxyethano of the contaminated water or deionized water solution at (23±1) centigrade should be (3.95±0.05) Omegala.
Power supply AC220 (±10%) V / 50 HZ
Instrument dimensions L1245 x W723 x H2295 (mm)

Frequently Asked Questions:-

 

What is Erosion Resistance Test?

Sandblasting rig, candidate erosion impact material samples to the function of the particle to ASTM G76-13 determine the capability of performing testing of characteristics according to resistance as an Impact velocity up to 150 m/s

What is 6KV High Voltage?

It measures the input impedance capability of Intended for low energy an AC/DC voltmeter to 6000 V peak designed to extend the voltage AC or DC. The probe provides high accuracy when Overvoltage Category I is used with a voltmeter having 10 MΩ. Applications

What’s considered high voltage?

Define high voltage as, and the National Electrical Manufacturer’s at least 1500 V for voltage as over 100 to direct current. In the United States, above 1000 V for alternating current Association (NEMA) defines as high 230 kV.

 

IEC 60587 High Voltage Tracking and Erosion Resistance Test Apparatus 

You can also check out our Machinery Products.

]]>