Electrical & Electronic - Tech Trivial https://www.techtrivial.com/product-category/electrical-electronic/ Cable & Electrical Test Equipments Suppliers Sat, 27 Apr 2024 08:15:24 +0000 en-US hourly 1 https://wordpress.org/?v=6.9 https://www.techtrivial.com/wp-content/uploads/2021/05/cropped-favi-32x32.png Electrical & Electronic - Tech Trivial https://www.techtrivial.com/product-category/electrical-electronic/ 32 32 Multifunctional LCR Meter with USB https://www.techtrivial.com/product/multifunctional-lcr-meter-with-usb/ Thu, 21 Oct 2021 09:03:24 +0000 https://www.techtrivial.com/?post_type=product&p=7112 Service Details:

Model Number:- D174

Accuracy: 0.3% with resolution of 0.01%

Power Source: Battery and external power supply

Display: Auto LCR smart check and measurement 19,999

Test Frequency: Measurement frequency up to 100KHz

 

Features:

Analogy bar display

Measurement frequency up to 100KHz

Basic accuracy: 0.3% with resolution of 0.01%

Data hold

Sorting function

Relative measurement

Mini – USB interface (KM 520B only)

Back light, full angle for LCD display

Battery and external power supply

4 – Terminal measurement configuration

Battery voltage indication

Automatic power off

It is precisely tested and high grade assortment of Multifunctional LCR Meter with USB.

 

 

]]>
AC DC True RMS Digital Clamp Meter https://www.techtrivial.com/product/ac-dc-true-rms-digital-clamp-meter/ Thu, 21 Oct 2021 08:59:50 +0000 https://www.techtrivial.com/?post_type=product&p=7148 This is an electrical test tool that has a basic digital multimeter with a current sensor. In this device, the clamp measures current, and the Probe measures voltage.

If we compare with a digital Multimeter which is essentially a voltage measuring tool with some current abilities whereas a clamp meter is a current measuring tool with some voltage abilities.

Every Tech Trivial Clamp Meter gives you exactly what you need: accurate measurements, consistent and reliable performance, best possible safety, and best possible warranty available.

Brand: Tech Trivial

Model: D3

Special Features:

It has Inrush Current Measuring Function for Direct Current (DC )and Alternate Current(AC)

Synchronous measurement of Inrush Current for measuring the true starting current for motors, lighting, breaker, etc

Features:

It has a four-digit display

It has a standard 9 Volt battery

DC Voltage: 0.1 V to 600 V

Frequency: 20 Hz to 400 Hz

Resistance: 0.1 ohm to 9999 ohm

Capacitance: 0.1 micro F to 9999.9 micro F

It has backlight

Dimension: 250* 100* 46

Auto power off

Low battery indicator

Instant continuity buzzer

Relative zero mode function

Digital Reading and High Accuracy,

ACA/DCA measurement up to 999.9A

Indoor use

Accessories with this Clamp Meter:

1. Test Leads,

2. Carrying case,

3. Installed Battery

4. User’s Manual

5. Banana plug k type thermocouple,

6. Thermocouple Adapter

Safety:

*All input are protected to En61010-1, CAT III 600 V

* Withstand Voltage: 6000 Volt

 

]]>
Resistance to Fire Alone https://www.techtrivial.com/product/resistance-to-fire-alone/ Tue, 19 Oct 2021 11:02:07 +0000 https://www.techtrivial.com/?post_type=product&p=7041 Specification Compliance:
  1. BS 6387
  2. IEC 60331-21
  3. IEC 60331-1/2/3/4
  4. Model Number:-D213

Features:

1. The middle portion of the cable is supported by 2 metals rings and three additional support

2. Resistance to fire alone test is compliant to IEC 60331-21 including

Short Circuit Detection

Open Circuit Detection

3. It has the unit is equipped with an appropriate circuit breaker with transformer protection and digital overload relay as specified in the test standard.

4. Fully automatic 3 single phase power supply

5. PLC microprocessor based control system

6. Automatic current adjustment

7. Automatic fault detection system

Model: D213

]]>
Micro Ohm Meter https://www.techtrivial.com/product/micro-ohm-meter/ Tue, 19 Oct 2021 11:00:28 +0000 https://www.techtrivial.com/?post_type=product&p=7028 Specification Compliance:

  1. IEC 60811
  2. IS 10810
  3. Model Number:-D204

Four wire measurement systems eliminate lead resistance error.

Microcontroller based instruments having an effective measuring range

Available and conductor resistance measurement with automatic temperature compensation

It has a complete solid-state design, ensures fast response, high accuracy, stability

Frequently asked questions:-

What is a micro ohm?    

The units of measure and resistances less than 1 Ohm One milliohm are equal to one-thousandth witch an ohm One micro ohm is equal to one-millionth of an ohm.

What is a micro ohmmeter used for?

The Micro-Ohmmeter resistance is used to measure extremely low and high accuracy at specified test currents and is used.

]]>
AC Current Transducer https://www.techtrivial.com/product/ac-current-transducer/ Tue, 19 Oct 2021 10:41:06 +0000 https://www.techtrivial.com/?post_type=product&p=7104 The offered transducer is manufactured using high-grade raw material and contemporary technology. We assure our clients that our transducer’s quality is tested on predefined parameters. Apart from this, our prestigious clients can avail this transducer as per their needs, at a highly competitive price in order to meet industry standards.

Features:

  • Dual display of temperature and humidity
  • Simultaneously hold both temperature & humidity readings
  • Stores up to 200 readings
  • Auto-Power Off with disable function
  • Simultaneously hold both Maximum & Minimum average readings (MAX/MIN/AVG) with time marks
  • Relative subtraction value (REL) function Select between different temperature scales (°C/°F)
  • Alarm alert (SET) function
  • DEW-POINT and WET-BULB temperature measurement
  • Backlight function
  • Low battery indication

 

SPECIFICATION

  • Input Burden: 0.3VA/60Hz, Self-Power Mode 3VA/60Hz.
  • Frequency: 45~70Hz or 400Hz.
  • Accuracy: 0.2%RO at 23°C ± 5°C (Self-Power Mode 0.25% RO at 23°C±5°C).
  • Output Load: DC Current Mode: 10V DC Maximum
  • Dielectric Strength – 2.6KVAC/1 Min, between Input/Power/Case
  • Impulse: 5KV (1.2X50ms ), NSI C37 .90a/1983. DIN, IEC 255-4, IEC688-1992
  • 2.5KV-0.25mS/1MHz IEC 801-3 (Ring WAVE)
  • Stability – <0.2% / Year
  • Calibration – SPAN and ZERO±10%
  • Response Time & Ripple (p-p): ≤400mS. 0~99%; 0.5% P-P(STD) or Option
  • Magnetic Effect: DIN-IEE688 ≤0.005% Change 10″ Centre 100A-Turn.
  • Common Mode Rejection: >120db, 50/60Hz.
  • Temperature Coefficient: ≤100ppm/°C from 0~60°C; ≤50ppm /23°C ± 3°C
  • Storage Condition: -40°C~+75°C, 20~95%RH Non-Condensed.
  • Operating Condition: -10°C~+65°C, 20~95% RH Non – Condensed.
  • Power Supply AC or DC ±20%, 50/60Hz 1¢ 3VA/AC: 3¢ 3VA/AC
  • Aux. Power Effect <0.01% / V
  • Mounting: DIN Rail or Wall Mounting
  • Size:  1© [ 50 X 115 X 73.4 mm ] ; 3 © [ 120 X 115 X 73.4 mm ]
  • Self-Power Mode: Effective Range 5~ 150%, Output 0~XmA DC
]]>
Multifunction Power Transducer with Display TRMT https://www.techtrivial.com/product/multifunction-power-transducer-with-display-trmt/ Tue, 19 Oct 2021 10:37:43 +0000 https://www.techtrivial.com/?post_type=product&p=7107 Service Details:

W van WH Vary PF Accuracy: +/- 0.5% F.S

Frequency Accuracy: +/-0.02Hz

Voltage and Current Accuracy: +/- 0.2% F.S

Model Number:-D154

Features:

Easy Installation & Space-saving

Frequency

Meets to DN-IEC 688

Individual Phase to neutral Voltage

Individual Phase watt

Simultaneous detect & display

Phase to Phase Voltages

Total Varo

Power Factor

Individual Phase Current

Total Watt

Watt Hour (10 digits)

Vat Hour (10 digits)

Circuit selection of 1f2W, 1f3W, 3f3W, 3f4W

Auto/Manual scrolling Display CT Ratio & PT Ratio – user settable on the instrument by front panel keys

RS 485 output

Analogy & Digital outputs available (Optional).

High Dielectric Strength: AC 2KV/min, between Input/output/Power/Case.

Band Rate user-selectable 2400/4800/960/19200/38400.

Digital outputs available for kohl & KVARH (Optional) Baud Rate: 1200, 2400,4800,9600,19200,38400 user selectable.

High Brightness LED Display. RS-485

Cable ABS plastic fire retardant case, DIN Rail & Wall Mounting Up to 255 units can be connected on single

]]>
Air oven-natural air change https://www.techtrivial.com/product/air-oven-natural-air-change/ Tue, 19 Oct 2021 10:31:49 +0000 https://www.techtrivial.com/?post_type=product&p=7020 Method 1: Based on Flow Meter Measurement The equipment is fitted with a Rotameter Method 2: Air Velocity Method Fresh air is admitted by the high capacity blower and controlled by means of a damper In this method, an air blow has an air velocity tunnel equipped with a differential air velocity measurement probe is connected to the oven.]]> Ref. Credit: ASTM D5346-1999 :

The air circulation within a forced-convection oven should be considered when loading specimens into the oven chamber. Forced-convection ovens are designed to provide uniform air temperature throughout the test chamber. This uniformity of air temperature is achieved by using baffles, or different sizes of holes, or both at the air inlet and outlet to and from the chamber.

The air flow within an oven is almost laminar at the air inlet and outlet and near the walls of the test chamber. The air is turbulent within the center of the chamber.

It has been noted that specimens positioned in the laminar air flow regions age faster than those in the turbulent region. The reason for this phenomenon is not understood, but it has been observed that the leading edges of flat specimens are a degree or two hotter than the trailing edge. There also may be a tendency for plasticizers to be stripped more rapidly from specimens in the laminar flow regions because of higher air velocity across the surface of the specimens.

For maximum reproducibility of test results, specimens should be placed in the turbulent air flow region. In an empty oven chamber, the turbulent flow region occupies the inner half of the chamber volume. This region increases somewhat with loading, depending upon specimen geometry and positioning. In any case, placement of specimens near the inlet or outlet ports should be avoided, because of the laminar air flow.

The temperature variation in a loaded oven may differ significantly from that measured in an empty oven. Therefore, the recommendation is to use a natural air change oven where air change can be directly measured and to make tests on a loaded oven, particularly with heavy loading, should be observed.

Standard Compliance:

  1. UL 44
  2. UL 94
  3. UL 1581
  4. UL 2556

 

]]>
SAE-J 1128 Automotive Cable Fire Resistance Testing Machine https://www.techtrivial.com/product/automotive-cable-fire-resistance-testing-machine/ Tue, 19 Oct 2021 10:30:05 +0000 https://www.techtrivial.com/?post_type=product&p=6783 SAE-J 1128 Automotive Cable Fire Resistance Testing Machine

Specifications:-

Collection plate:-L336 * W85 * H12 mm

Combustion gas:-High purity liquefied petroleum gas

Dimension:-L1200 * W800 * H600 mm

Flame height:-38 mm adjustable

Standard:-SAE-J 1128

Power:-Electronic

Test Material:-Vehicle Wire & Cable

Model Number:-D361

Power supply:-AC220V, 50HZ

Nozzle inner diameter:-0.375 inches (9.5mm)

Material:-SUS 304 Stainless Steel

Main Technical Parameters
Dimension of the combustion chamber L420 x W205 x H370 mm
Sample Jig This machine fixture is used for standard sample has 2 sets of U jig. One set of sample preparation (100 mm), the sample preparation other set is used for non-standard (< 80 mm).
Flame / burning time 0 ~ 99.99 s/min/h set at random
Burning lamp Nozzle with inner angle is 90 degree, nozzle diameter of 9.5 mm, burning length is 100 mm.
Gas source High purity liquefied gas (customer owned)
Flame height 38 mm adjustable
Metal comb L110 x W40 x H5 (mm)
Collection plate Material is stainless steel, size: L336 x W85 x H12 mm
Combustion chamber contour dimension L1200 x W800 x H600 (mm)
Nozzle Ф9.5 mm, with flame adjustment function, blue flame height: 38 mm
Work power supply AC220V, 50HZ

 

Frequently Asked Questions:-

What is fire resistant cable used for?

In brief, flame the spread of fire is designed to maintain into a new area. Fire retardant cables are designed to integrity and continue to work for rated cables a resist resistant or fire circuit specified period of time under defined conditions.

What is cable testing?

A cable test is an validation of two wires in an antenna connection specific test area or integrated into an automatic cable or the harness electrical test and it can be the simple of a plane points The cable test can be processed in a including more than 60.000 production environment.

What is difference between FR and FRLS cable?

FR PVC insulation has normal PVC. FRLS PVC insulation properties than better fire retardant emit then normal PVC & also provide better fire retardant properties Low Smoke, in case of fire.

 

D361 | SAE-J 1128 Automotive Cable Fire Resistance Testing Machine

 

You can also check out our more Machinery Products.

]]>
ISO 1716 Calorific Value Testing Equipment For Building Materials https://www.techtrivial.com/product/calorific-value-testing-equipment-for-building-materials/ Tue, 19 Oct 2021 10:27:44 +0000 https://www.techtrivial.com/?post_type=product&p=6681 Specifications:-

Warranty of Calorific Value Testing Equipment For Building Materials:-1 Year Flame

Model Number:-D247

Power supply:-220V 50Hz

Power:-Electronic

Application:-Building Materials

Material:-SUS 304 Stainless Steel

Standard:-ISO 1716

Height:-20 ± 2 MM

Temperature Control Range:-25 ~ 35 ℃

Calorific Value of Combustion:-0.01 MJ/kg ~ 30 MJ/kg

Combustion Chamber:-L700 * W400 * H810 MM

Technical parameters

Total calorific value of combustion 0.26 MJ/kg ~ 40 MJ/kg
Repeatability error of combustion calorific value Dynamic ≤ 0.1%
Temperature probe test range 0℃ ~ 40℃
Temperature resolution 0.0001℃, using semiconductor sensor
Oxygen bomb volume 300 ml, mass: 3.2 kg
Inner cylinder volume 2200 ml
No air leakage When the oxygen charging pressure of oxygen bomb is 0 ~ 3.5Mpa
Endurance of oxygen bomb ≥ 21 MPa water pressure
Mixing power 3W
Mixing speed 375 r/min
Ignition circuit The voltage is 12V and the diameter of ignition wire is 0.1mm copper wire
Thickness of the shell Greater than 1/10 of the inner diameter of the barrel
Inner wall of the barrel SUS304 stainless steel, which can withstand the corrosion of combustion products of the sample, as well as the pitting corrosion and intergranular corrosion caused by the acid substances produced by combustion
Outer cylinder of the calorimeter Double-layer container with an insulating cover.  The inner and outer walls of the calorimeter are filled with insulating materials. The outer cylinder is filled with water. There is a gap of 10 mm between the inner wall of the outer wall and the surrounding of the calorimeter. The shell is supported by three
points with the smallest contact area.
Inner cylinder of calorimeter It is a polished metal container used to contain oxygen bomb, which can make oxygen bomb completely invade water. Inner cylinder
automatic water injection device, if there is a lack of test water, the equipment will automatically supplement.
Pressure gauge and needle valve Installed on the oxygen supply circuit to display the pressure of oxygen bomb during oxygen charging, accurate to 0.1MPa
Method Crucible method (or cigarette method can also be used)
Working power supply AC220 V, 50 Hz
Total power 150W
Equipment dimension L530mm x W570mm x H984mm

Frequently Asked Questions:-

What is calorific value?    

Calorific value in Calorific Value Testing Equipment For Building Materials is a measure of the amount of energy produced from a unit weight of coal when it is combusted in oxygen. A measured sample of coal is completely combusted in a bomb calorimeter, which is a device for measuring heat (ASTM method D5865-12; American Society for Testing and Materials, 2013, p. 648–666).

]]>
Automatic Cable Rubber Plastic Specimen Chipper https://www.techtrivial.com/product/automatic-cable-rubber-plastic-specimen-chipper/ Tue, 19 Oct 2021 10:24:21 +0000 https://www.techtrivial.com/?post_type=product&p=6425 Automatic Cable Rubber Plastic Specimen Chipper

Specifications:-

Maximum feed thickness:-10 mm

Material:-SUS 304 Stainless Steel / Baking Finish

Warranty:-1 Year

Working face width:-90 mm

Power:-Electronic, 380V 0.75KW 50HZ

Model Number:-D425

Standard:-GB/T2951

Slice thickness:-1 – 10 mm

Cutting speed:-0-6 cm/s

Product Description

Automatic Cable Rubber Plastic Specimen Chipper

 Overview:-



This machine rolls rolling. The rolled without the surface of the test piece,  sample communication cable specified avoids adopts steel toothed roller the mechanical damage on can be placed and in GB/T2951-97 “General Test horizontally, and replaced so that the blade regrind, and fully The operating principle requirements of the equipment for preparing samples which shall be applicable to the matching conforms to GB/T2951-97. cable Methods for Wire and Cable polymer insulation and sheathing and sheathed Materials”, including materials for marine cables, mechanical and physical and specimen equipment for performance testing.

 Main parameters:-
Working face width 90 mm
Maximum feed thickness 10 mm
Slice thickness 1 – 10 mm
Cutting speed 0-6 cm/s
Input power 380V 0.75KW 50HZ

Frequently Asked Questions:-

What is the automotive cable?

Automotive in cars, trucks and trailers intended for use in starters and Common is used for electric brakes for and wire include general circuit wiring brake wiring in applications primary cable engine compartments while battery cable is battery ground circuits.

What’s Chipper mean?

Chipper is the most upbeat, cheerful, and outward way. Chipper is a mood or high-spirited, especially commonly used as an adjective meaning in attitude, used to describe someone’s overall or their actions.

What is a chipper used for?

A wood chipper (also known as a tree chipper) is a machine that is used to clean up after vegetation cut tree limbs, trunks, and. They make maintenance branches into chips a lot less arduous.

What is the difference between a chipper and a shredder?

A wood chipper is branches or larger pieces of wood specially designed for handling larger and then chips. A makes breaking them down into smaller wood shredder, on the other hand, use of the blunt, leaving it in a state where it is edges to crush or pull apart the material ready for compost.

You can also check out our more Machinery Products.

]]>